Skip to main content
INDEPENDENT STUDY RESOURCE · NOT AFFILIATED WITH THE U.S. EPA
ASHRAE 34 · AHRI GUIDELINE N · DOT 4BA/4BW

EPA 608 Refrigerant Types, Safety Classes & Recovery Cylinders

Understand chemical families (CFC, HCFC, HFC, HFO, HC), ASHRAE 34 toxicity/flammability ratings, and DOT recovery tank rules—then drill the questions right below.

Refrigerant Chemical Families & Phaseout Status

Family Elements ODP GWP Examples & Regulatory Status
CFC (Class I ODS) Cl, F, C Highest (0.6–1.0) Very High R-11, R-12, R-500, R-502. Production/import banned Jan 1, 1996.
HCFC (Class II ODS) H, Cl, F, C Low (0.02–0.055) Moderate–High R-22 (virgin banned Jan 1, 2020), R-123 (new equip banned 2020; prod ends 2030).
HFC H, F, C (No Cl) 0 High (675–3922) R-134a, R-410A, R-404A, R-407C, R-32. Phasing down 85% by 2036 (AIM Act).
HFO & HFO Blends H, F, C (unsaturated) 0 Ultra-Low (1–466) R-1234yf, R-1233zd(E), R-454B, R-514A. Short atmospheric life.
Hydrocarbons (HC) H, C only 0 ~3 R-290 (propane), R-600a (isobutane). ASHRAE A3 flammable; SNAP charge limits.

ASHRAE Standard 34 Matrix & DOT Recovery Cylinder Rules

ASHRAE 34 Toxicity + Flammability

  • A1: Lower toxicity, no flame propagation (R-22, R-134a, R-410A, R-1233zd).
  • A2L: Lower toxicity, mildly flammable, slow burn velocity ≤10 cm/s (R-32, R-454B, R-1234yf).
  • A3: Lower toxicity, higher flammability (R-290, R-600a).
  • B1 / B2L: Higher toxicity (R-123 = B1; R-717 ammonia = B2L).

DOT Recovery Cylinder Checklist

  • Color: Gray body with yellow top/shoulder.
  • Fill Limit: Never exceed 80% liquid capacity (20% vapor expansion space).
  • Retest: Hydrostatic pressure test every 5 years (stamped on collar).
  • R-410A / A2L Rating: Minimum 400 psig DOT 4BA400/4BW400; never mix refrigerants!
TYPES-DRILL 14 Questions · 72% Pass Line

Refrigerant Types, 3 Rs & Cylinder Rules Drill

Q 1 / 14 Loading topic…
Score: 0/0

Which ASHRAE Standard 34 safety classification applies to mildly flammable, lower-toxicity refrigerants like R-32 and R-454B?

Refrigerant Types & Cylinders FAQ

Are disposable refrigerant cylinders still color-coded by refrigerant type?

AHRI Guideline N transitioned away from individual pastel tank colors for virgin refrigerant cylinders toward a uniform light blue-gray cylinder with clear printed labels—because dozens of new blends made colors confusing. However, refillable DOT RECOVERY cylinders remain strictly standardized: gray body with a yellow top/shoulder, and flammable A2L/A3 cylinders carry a red band.

Why must 400-series refrigerant blends be charged as a liquid?

400-series refrigerants are zeotropic blends composed of chemicals with different boiling points. Drawing vapor from the top of the cylinder pulls off the lowest-boiling component faster (fractionation), leaving an off-ratio charge.